- 10-year retrospective study of 32 patients with transverse patellar fractures.
- 28.1% failure rate due to wire slippage and breakage.
- Median time to failure was 58 days.
- Longer K-wire lengths associated with failure.
- Single-knot constructs had a 66.7% failure rate.
- No failures linked to sex, BMI, or height.
- Key injury mechanisms included high-energy falls and traffic accidents.
- Emphasis on appropriate implant selection in surgeries.
Radiographic Predictors of Tension Band Wiring Failure in Patellar Fractures
Conexiant
July 31, 2025